***Price Is Per Meter***
One step forward, one step back...
round and round, don???t break your neck! When data need to be passed back and forth, a digital cable with a check-back channel should be used. The wave impedance of this cable is also specified at 110 ??. Two of the 4 wires are responsible for the check-back function. The sturdy jacket is suitable both for outdoor and permanent installation.
Colour coding according to DIN 47100.
Due to the dual shielding (AL/PT foil + copper braiding) and wire coding it conforms with the generally applicable guidelines (VDE 0812/VDE 0207). Transmission rate 256 Kbs according to EIA 485 standard.
Advantages:
- Digital transmission over long distances due to the DMX and AES/EBU standards
- Excellent protection against electric interference (Cu mesh screen + AL/PT foil)
- Extremely robust due to the special tough jacket
Application:
- Networking of scanners and lighting systems with check-back function
- Connection of digital control units and devices of all kinds
Specifications:
Article number | 540-0056 |
---|---|
Name | Binary 434 DMX512 |
EAN | 4049371002394 |
Properties | OFC oxygen free copper |
Properties | Analog |
Properties | Digital 110 ?? AES / EBU |
Application area | Installation |
Application area | Studio / Broadcast |
Application area | Mobile outdoor / indoor |
Application area | ELA 100 V |
Application area | Stage / live |
Application | DMX |
Colour | grey |
Colour detailed | grey |
Signal transmission | symmetrical |
Construction | [2(2LI2YS0,34mm??)(ST)]CY |
Jacket material | PVC |
Jacket ?? [mm] | 7,00 |
Number of Channels (AES/EBU, DMX) | 1 |
Inner conductor (AES/EBU, DMX) | 4 |
Inner conductor (AES/EBU, DMX) [mm??] | 0,34 |
Inner conductor ?? (AES/EBU, DMX) [mm] | 0,66 |
AWG (AES/EBU, DMX) | 22 |
Shielding | Copper-cross mesh, tined + AL / PT foil |
Shielding factor [%] | 100 |
Copper strands (AES/EBU, DMX) | 7 |
Copper strand ?? (AES/EBU, DMX) [mm] | 0,25 |
Conductor insulation material | PE |
Conductor insulation ?? [mm] | 1,70 |
Weight per 1 m [g] | 65 |
Fire load per m [kWh] | 0,22 |
Style variant | round |
Packing | 100 m spool |
Temperature min. [??C] | -25 |
Temperature max. [??C] | 70 |
Width [mm] | 7 |
Height [mm] | 7 |
Capac. cond./cond. per 1 m (AES/EBU, DMX) [pF] | 58 |
Capacity wire/wire at 1 ft. (AES/EBU, DMX) [pF] | 17,6784 |
Capac. cond./shield. per 1 m (AES/EBU, DMX) [pF] | 100 |
Capacity wire/electic screen at 1 ft. (AES/EBU, DMX) [pF] | 30,48 |
Impedance [??] | 110 |
Insulation resist. per 1 km [G??] | 5 |
Insulation resist. per 1000 feet [G??] | 1,524 |
Insulation resist. per 1 km (AES/EBU, DMX) [G??] | 5 |
Insulation resist. per 1000 feet (AES/EBU, DMX) [G??] | 1,524 |
Conductor resistance per 1 km [??] | 53 |
Conductor resistance per 1000 ft. [??] | 16,1544 |
Shield. resistance per 1 km [??] | 15 |
Shield. resistance per 1000 ft. [??] | 4,572 |
BPVo-Euroclass | Fca |